Technical Specifications

View the technical specifications for MCPA performance spaces.

The Thomas, Kathleen & William Donnell Theater

Contact & Info

Venue Info

  • Address: 200 W. Main Cross Street, Findlay, OH 45840
  • Phone: 419.423.2787
  • Technical Director: 

Emergency Information

  • Findlay Police: 419.424.7150
  • Findlay Fire: 419.424.7129
  • Blanchard Valley Hospital: 1900 South Main Street, Findlay, OH 4584
  • Blanchard Valley Hospital Phone: 419.423.4500
  • Kroger Pharmacy: 101 6th Street, Findlay, OH 45840 419.423.2065
  • CVS Pharmacy: 433 Tiffin Avenue, Findlay, OH 45840 419.422.3192

Amenities 

  • City Cleaners
    • 116 E Main Cross Street, Findlay, OH 4584
      419.422.7924
    • Open Mon‐Fri 7 AM‐6 PM; Sat 9 AM 1 PM
  • A‐1 Auto Repair 
    • 333 N Cory Street, Findlay, OH 45840
      419.427.1330
    • Open Mon‐Fri 8 AM‐5 PM
  • Walmart Auto Center 
    • ​​​​​​​1161 W Trenton Avenue, Findlay, OH 45840 419.425.3928
    • Open 24/7

Technical Specifications

Backstage

  • Dressing Rooms: 3 individual w/ private shower, bathrooms, mirrors. Stage level 2 chorus w/ showers, bathrooms. Lower level with elevator access
  • Green Room: 1 with refrigerator, microwave, coffee maker, couch. Stage level
  • Bathrooms: 2 accessible bathrooms. Stage level.
  • Loading Dock: 2 rolling doors at semi‐truck height with direct path to stage from dock

House

  • Seats: 969 Seats
    566 in orchestra
    152 in mezzanine
    251 in balcony
  • Booths: Light booth in back of house, behind glass Sound booth in back of house, under balcony
  • Stage: Proscenium 43’ X 20’
    Plaster Line to US Wall 37’ 9”
    Width of Stage Deck 87’ 4”
    Plaster Line to Booth 76’ 8”
    Deck to Grid 55’ 3”
    Orchestra lift 8’‐ 4” x 36’
  • Stage Electrics: 2 400amp 3 phase cam‐lock or bare wire
    1 200amp 3 phase cam‐lock or bare wire (iso)
    Male ground + double neutral
    Motorized 1st electric + FOH 2nd electric
    Cable pass through from SR to FOH (125’) and SR to Orchestra pit

Lighting

  • 3 Sensor 3 dimmer racks
  • 14 ETC Gateways
  • Enet connections Sound Booth, Light Booth, Mid‐House, Backstage Right ETC Ion (2 full Universes)
     
  • DMX Hook‐ups: 8 above stage
    • 2 stage right
    • 2 light booth
    • 2 sound booth
    • 2 mid house
    • 2 mid house pipe
    • 2 attic
  • Circuits: 44 on deck
    • 72 above stage
    • 18 attic
    • 12 mid house pipe
    • 26 box bombs
  • Dimmers: 128 on stage
    • 58 in house